By Pass System RCD-1 to SP-3 RCD-2 to SP2Pelabuhan Batubara Tarahan
PT. Protech Asia Engineering.
CALCULATION OF BY PASS CONVEYOR C - 12A
1 Belt Capacity Required t/h 825
2 Belt Width B mm 1200
3 Belt Speed Required v m/s 1.13
4 Angle of Inclination φ 12.8
5 Belt Center Distance L m 154.4
Vertical height to elevate= Lsi H m 18
Skirt board length each side m 3 sbl = 6
6 Material / Bulk density ץ 1.4
7 Capacity Factor k 0.89 H/L = 0.28
8 Trough Angle λ 35 β 10
9 Total Moisture % 28
Material Temperature 35
Lump Size mm 100
10 Weight of Moving Part Conv. G kg/m 45 see table 7
if s1 and s2 and density < 1.5 s1 m 1 see table 7
s2 m 3 see table 7
11 Additional l m 100 see table 8
if center distance >100 m. L m 154.4 see table 8
12 Coefficient of friction of rolling parts
parts f 0.023 see table 9
Check Theoritical Capacity Qt
1 Qt' = = 584.22m3/h
See table 4, choice the Qt' corresponding with Belt width, trough angle, basic angle and find out;
Q't = 614 m3/h
with ;
Belt Width B mm 1200
Trough Angle λ 35 β 15
2 Qt = Q't x v x k = 619.32 m3/h
3 Q = = 867.05 t/h
Q2
o
t/m3
o o
oC
{Q2/(v x ץ x k)}
o o
Qt x ץ
Q > Q2

By Pass System RCD-1 to SP-3 RCD-2 to SP2Pelabuhan Batubara Tarahan
PT. Protech Asia Engineering.
Power Requirement
1 Power Required to drive empty Conveyor N1 (kW)
= {G(L+l)fxv}/102 = 2.93 kW
2 Power Required to convey material on the level N2 (kW)
= {Q(L+l)f}/367 = 13.82 kW
3 Power Required to elevated material N3 (kW )
= (QxH)/367 = 42.53 kW
4 Additional Power Requirement N4 (kW), see table 10
= = 0.54 kW
* Theoritical Necessary Motor Capacity Nn (kW)
Nn = = 59.82 kW
* Motor Capacity (Nm)
Nm = Nn / ŋ = 70.38 Kw
* Recommended Pulley Diameter (mm) for Multiply Belt (4PN150) with 65% ~ 100 % utilization;
see table 16
D1 = Driving Pulley = 500 mm D1 = 733 mm
D2 = Tail Pulley = 400 mm D2 = 530 mm
D3 = Snub Pulley = 315 mm D3 = 330 mm
GEAR REDUCER SELECTION
Service Factor sf= 2
* Nominal Power Rating = Pm x sf = 140.75 kW
* Gear Reducer output speed = (v x 60)/(3.14 x D1) = 29.54 rpm
* Gear Reducer Ratio i = = 50.77
* Thermal Rating = = 149.29 kW
= 143
According above mention , choice gear reducer type and size ;
FLENDER type : B3HH11 i = 50 or
HANSEN P4 type: QHRF3 i = 50
N1
N2
N3
N40.08x v x length of
skirt board
N1 + N2 + N3 + N4
PN
n2
1500 / n2
PG PG1 x 0.87 x 1.2
PG1
PN < PG the Gear Reducer no need extra cooling.

By Pass System RCD-1 to SP-3 RCD-2 to SP2Pelabuhan Batubara Tarahan
PT. Protech Asia Engineering.

By Pass System RCD-1 to SP-3 RCD-2 to SP2Pelabuhan Batubara Tarahan
PT. Protech Asia Engineering.
See table 4, choice the Qt' corresponding with Belt width, trough angle, basic angle and find out;

By Pass System RCD-1 to SP-3 RCD-2 to SP2Pelabuhan Batubara Tarahan
PT. Protech Asia Engineering.
Recommended Pulley Diameter (mm) for Multiply Belt (4PN150) with 65% ~ 100 % utilization;

By Pass System RCD-1 to SP3 RCD-2 to SP2Pelabuhan Batubara Tarahan.
PT. Protech Asia Engineering.
CALCULATION OF BY PASS CONVEYOR C - 12A
1 Belt Capacity Required t/h 1650
2 Belt Width B mm 1200
3 Belt Speed Required v m/s 4.5
4 Angle of Inclination φ 16
5 Belt Center Distance L m 15.5
Vertical height to elevate= Lsi H m 4.06
Skirt board length each side m 3 sbl = 6
6 Material / Bulk density ץ 0.9
7 Capacity Factor k 0.89 H/L = 0.28
8 Trough Angle λ 35 β 10
9 Total Moisture % 28
Material Temperature 35
Lump Size mm 100
10 Weight of Moving Part Conv. G kg/m 45 see table 7
if s1 and s2 and density < 1.5 s1 m 1.5 see table 7
s2 m 3 see table 7
11 Additional l m 50 see table 8
if center distance < 30 m. L m 15.5 see table 8
12 Coefficient of friction of rolling parts
parts f 0.023 see table 9
Check Theoritical Capacity Qt
1 Qt' = = 457.76m3/h
See table 4, choice the Qt' corresponding with Belt width, trough angle, basic angle and find out;
Q't = 493 m3/h
with ;
Belt Width B mm 1200
Trough Angle λ 20 β 15
2 Qt = Q't x v x k = 1974.47 m3/h
3 Q = = 1777.02 t/h
Q2
o
t/m3
o o
oC
{Q2/(v x ץ x k)}
o o
Qt x ץ
Q > Q2

By Pass System RCD-1 to SP3 RCD-2 to SP2Pelabuhan Batubara Tarahan.
PT. Protech Asia Engineering.
Power Requirement
1 Power Required to drive empty Conveyor N1 (kW)
N1 = {G(L+l)fxv}/102 = 2.99 kW
2 Power Required to convey material on the level N2 (kW)
N2 = {Q(L+l)f}/367 = 7.29 kW
3 Power Required to elevated material N3 (kW )
N3 = (QxH)/367 = 19.66 kW
4 Additional Power Requirement N4 (kW), see table 10
N4 = = 2.16 kW
* Theoritical Necessary Motor Capacity Nn (kW)
Nn = N1 + N2 + N3 + N4 = 32.10 kW
* Motor Capacity (Nm)
Nm = Nn / ŋ = 37.77 Kw
* Recommended Pulley Diameter (mm) for Multiply Belt (4PN150) with 65% ~ 100 % utilization;
see table 16
D1 = Driving Pulley = 500 mm D1 = 630 mm
D2 = Tail Pulley = 400 mm D2 = 530 mm
D3 = Snub Pulley = 315 mm D3 = 330 mm
GEAR REDUCER SELECTION
Service Factor sf= 2
* Nominal Power Rating PN = Pm x sf = 75.54 kW
* Gear Reducer output speed n2 = (v x 60)/(3.14 x D1) = 136.49 rpm
* Gear Reducer Ratio i = 1500 / n2 = 10.99
* Thermal Power Rating = = 53.24 kW
= 51
PN < PG the Gear Reducer no need extra cooling.
According above mention , choice gear reducer type and size ;
FLENDER type : B2HH4 i = 11.2 or
HANSEN P4 type: QHRA2 i = 11.2
0.08x v x length of skirt board
PG PG1 x 0.87 x 1.2
PG1

By Pass System RCD-1 to SP3 RCD-2 to SP2Pelabuhan Batubara Tarahan.
PT. Protech Asia Engineering.

By Pass System RCD-1 to SP3 RCD-2 to SP2Pelabuhan Batubara Tarahan.
PT. Protech Asia Engineering.
See table 4, choice the Qt' corresponding with Belt width, trough angle, basic angle and find out;

By Pass System RCD-1 to SP3 RCD-2 to SP2Pelabuhan Batubara Tarahan.
PT. Protech Asia Engineering.
Recommended Pulley Diameter (mm) for Multiply Belt (4PN150) with 65% ~ 100 % utilization;

CALCULATION OF BY PASS CONVEYOR C - 12A
1 Belt Capacity Required t/h 1650
2 Belt Width B mm 1200
3 Belt Speed Required v m/s 4.5
4 Angle of Inclination φ 16
5 Belt Center Distance L m 17
Vertical height to elevate= Lsinφ H m 4.06
Skirt board length each side m 3 sbl = 6
6 Material / Bulk density ץ 1.1
7 Capacity Factor k 0.89 H/L = 0.28
8 Trough Angle λ 35 β 10
9 Total Moisture % 28
Material Temperature 35
Lump Size mm 100
10 Weight of Moving Part Conv. G kg/m 67 see table 7
if s1 and s2 and density < 1.5 m 1.5 see table 7
m 3 see table 7
11 Additional l m 50 see table 8
if center distance < 30 m. L m 17 see table 8
12 Coefficient of friction of rolling
parts, on dusty running periodic f 0.03 see table 9
overloaded.
Check Theoritical Capacity Qt
1 Qt' = = 374.53m3/h
See table 4, choice the Qt' corresponding with Belt width, trough angle, basic angle and find out;
Q't = 396 m3/h
with ;
Belt Width B mm 1000
Trough Angle λ 30 β 15
2 Qt = Q't x v x k = 1585.98 m3/h
3 Q = = 1744.58 t/h
Q2
o
t/m3
o o
oC
s1
s2
{Q2/(v x ץ x k)}
o o
Qt x ץ
Q > Q2

No need to modify the speed , belt size , trough angle
Power Requirement
1 Power Required to drive empty Conveyor N1 (kW)
N1 = {G(L+l)fxv}/102 = 5.94 kW
2 Power Required to convey material on the level N2 (kW)
N2 = {Q(L+l)f}/367 = 9.55 kW
3 Power Required to elevated material N3 (kW )
N3 = (QxH)/367 = 19.30 kW
4 Additional Power Requirement N4 (kW), see table 10
N4 = = 2.16 kW
* Theoritical Necessary Motor Capacity Nn (kW)
Nn = N1 + N2 + N3 + N4 = 36.96 kW
* Motor Capacity (Nm)
Nm = Nn / ŋ = 43.48 Kw
Can use the motor 45 kW / 55 kW ( Nm x 1.25 for normal starting service factor )
* Recommended Pulley Diameter (mm) for Multiply Belt (4PN150) with 65% ~ 100 % utilization;
see table 16
D1 = Driving Pulley = 500 mm D1 = 630 mm
D2 = Tail Pulley = 400 mm D2 = 530 mm
D3 = Snub Pulley = 315 mm D3 = 330 mm
GEAR REDUCER SELECTION
* Prime Mover
Electric motor P1 = 55 kW
Motor speed n1 = 1500 rpm
Max. starting torque = 525 Nm
* Driven machine
Belt Conveyor = 45 kW
* Output rotation need = ( v x 60 )/( 3.14 x D1 ) = 136.49 rpm
* Gear Reducer Ratio i = = 10.99
0.08x v x length of skirt board
TA
P2
n2
n1 / n2

* Service factor for Gear Units with 24 hours operation.
Factor for driven machine Belt onveyor. = 1.30 table 1, page 12
Factor for prime mover use electric motor = 1.00 table 2, page 12
Peak torque factor with load peaks per hour 6 - 30 = 0.95 table 3, page 12
Thermal factor = 0.71 table 4, page 12
Thermal factor with cooling = 1.19 table 5, page 12
Factor for altitude = 1.00 table 6, page 12
Factor for altitude with cooling = 1.00 table 7, page 12
Oil supply factor for horz. = 0.95 table 8, page 13
Thermal capacity = 1.20 table 9, page 13
Thermal capacity factor with fan = 1.49 table 10, page 13
* Determination of Nominal Power ≥ = 58.50 kW
rating
* page :22
= = 149.85 kW
149.85 kW > PN = 82 kW
* Checking the starting torque ≥ = 78.34 kW
* Thermal Power Rating without = 51 page:23
auxiliary cooling
* Thermal capacity for gear units = = 41.28 kW
without auxiliary cooling
Gear unit need auxiliary fan cooling
Check thermal power rating with auxiliary fan cooling
* Thermal Power Rating with = 67 page:23
auxiliary fan cooling
* Thermal capacity for gear units = = 67.34 kW
with auxiliary fan cooling
f1
f2
f3
f4
f5
f6
f7
f8
f9
f10
PN P2 x f1 x f2
Selected from power rating table: type B2 gear unit size 4 , with PN = 81 kW
3.33 x P2 ≥ PN
PN (TA x n1) / 9550 x f3
PN = 81 kW > 78.34 kW
PG1
PG PG1 x f4 x f6 x f8 x f9
PG = 41.28 kW < P2 = 45 kW
PG2
PG PG2 x f4 x f6 x f8 x f10
PG = 67.88 kW > P2 = 45 kW

According above mention , choice gear reducer type and size ;
FLENDER type : B2DH4 i = 11.2
Hollow Shaft for shrink disk mounted, Right Angle with auxiliary cooling fan
`

m3/h
See table 4, choice the Qt' corresponding with Belt width, trough angle, basic angle and find out;
m3/h
m3/h

63.2238
54.347
Can use the motor 45 kW / 55 kW ( Nm x 1.25 for normal starting service factor )
59.129 63.937 power yang diminta
Recommended Pulley Diameter (mm) for Multiply Belt (4PN150) with 65% ~ 100 % utilization;
752

table 1, page 12
table 2, page 12
table 3, page 12
table 4, page 12
table 5, page 12
table 6, page 12
table 7, page 12
table 8, page 13
table 9, page 13
table 10, page 13
150
97.5


By Pass System RCD-1 to SP3 RCD-2 to SP-2Pelabuhan Batubara Tarahan
PT. Protech Asia Engineering.
CALCULATION OF BY PASS CONVEYOR C - 12A
1 Belt Capacity Required t/h 1650
2 Belt Width B mm 1200
3 Belt Speed Required v m/s 4.5
4 Angle of Inclination φ 16
5 Belt Center Distance L m 15.5
Vertical height to elevate= Lsinφ H m 4.06
Skirt board length each side m 3 sbl = 6
6 Material / Bulk density ץ 1.1
7 Capacity Factor k 0.89 H/L = 0.28
8 Trough Angle λ 35 β 10
9 Total Moisture % 28
Material Temperature 35
Lump Size mm 100
10 Weight of Moving Part Conv. G kg/m 67 see table 7
if s1 and s2 and density < 1.5 m 1.5 see table 7
m 3 see table 7
11 Additional l m 50 see table 8
if center distance < 30 m. L m 15.5 see table 8
12 Coefficient of friction of rolling
parts, on dusty running periodic f 0.03 see table 9
overloaded.
Check Theoritical Capacity Qt
1 Qt' = = 374.53m3/h
See table 4, choice the Qt' corresponding with Belt width, trough angle, basic angle and find out;
Q't = 396 m3/h
with ;
Belt Width B mm 1000
Trough Angle λ 30 β 15
2 Qt = Q't x v x k = 1585.98 m3/h
3 Q = = 1744.58 t/h
No need to modify the speed , belt size , trough angle
Q2
o
t/m3
o o
oC
s1
s2
{Q2/(v x ץ x k)}
o o
Qt x ץ
Q > Q2

By Pass System RCD-1 to SP3 RCD-2 to SP-2Pelabuhan Batubara Tarahan
PT. Protech Asia Engineering.
Power Requirement
1 Power Required to drive empty Conveyor N1 (kW)
N1 = {G(L+l)fxv}/102 = 5.81 kW
2 Power Required to convey material on the level N2 (kW)
N2 = {Q(L+l)f}/367 = 9.34 kW
3 Power Required to elevated material N3 (kW )
N3 = (QxH)/367 = 19.30 kW
4 Additional Power Requirement N4 (kW), see table 10
N4 = = 2.16 kW
* Theoritical Necessary Motor Capacity Nn (kW)
Nn = N1 + N2 + N3 + N4 = 36.61 kW
* Motor Capacity (Nm)
Nm = Nn / ŋ = 43.07 Kw
Can use the motor 45 kW / 55 kW ( Nm x 1.25 for normal starting service factor )
* Recommended Pulley Diameter (mm) for Multiply Belt (4PN150) with 65% ~ 100 % utilization;
see table 16
D1 = Driving Pulley = 500 mm D1 = 630 mm
D2 = Tail Pulley = 400 mm D2 = 530 mm
D3 = Snub Pulley = 315 mm D3 = 330 mm
GEAR REDUCER SELECTION
* Prime Mover
Electric motor P1 = 55 kW
Motor speed n1 = 1500 rpm
Max. starting torque = 525 Nm
* Driven machine
Belt Conveyor = 45 kW
* Output rotation need = ( v x 60 )/( 3.14 x D1 ) = 136.49 rpm
* Gear Reducer Ratio i = = 10.99
0.08x v x length of skirt board
TA
P2
n2
n1 / n2

By Pass System RCD-1 to SP3 RCD-2 to SP-2Pelabuhan Batubara Tarahan
PT. Protech Asia Engineering.
* Service factor for Gear Units with 24 hours operation.
Factor for driven machine Belt onveyor. = 1.30 table 1, page 12
Factor for prime mover use electric motor = 1.00 table 2, page 12
Peak torque factor with load peaks per hour 6 - 30 = 0.95 table 3, page 12
Thermal factor = 0.71 table 4, page 12
Thermal factor with cooling = 1.19 table 5, page 12
Factor for altitude = 1.00 table 6, page 12
Factor for altitude with cooling = 1.00 table 7, page 12
Oil supply factor for horz. = 0.95 table 8, page 13
Thermal capacity = 1.20 table 9, page 13
Thermal capacity factor with fan = 1.49 table 10, page 13
* Determination of Nominal Power ≥ = 58.50 kW
rating
* page :22
= = 149.85 kW
149.85 kW > PN = 82 kW
* Checking the starting torque ≥ = 78.34 kW
* Thermal Power Rating without = 51 page:23
auxiliary cooling
* Thermal capacity for gear units = = 41.28 kW
without auxiliary cooling
Gear unit need auxiliary fan cooling
Check thermal power rating with auxiliary fan cooling
* Thermal Power Rating with = 67 page:23
auxiliary fan cooling
* Thermal capacity for gear units = = 67.34 kW
with auxiliary fan cooling
According above mention , choice gear reducer type and size ;
FLENDER type : B2HH4 i = 11.2
Hollow Shaft for shrink disk mounted, Right Angle with auxiliary cooling fan
f1
f2
f3
f4
f5
f6
f7
f8
f9
f10
PN P2 x f1 x f2
Selected from power rating table: type B2 gear unit size 4 , with PN = 81 kW
3.33 x P2 ≥ PN
PN (TA x n1) / 9550 x f3
PN = 81 kW > 78.34 kW
PG1
PG PG1 x f4 x f6 x f8 x f9
PG = 41.28 kW < P2 = 45 kW
PG2
PG PG2 x f4 x f6 x f8 x f10
PG = 67.88 kW > P2 = 45 kW

By Pass System RCD-1 to SP3 RCD-2 to SP-2Pelabuhan Batubara Tarahan
PT. Protech Asia Engineering.
`

By Pass System RCD-1 to SP3 RCD-2 to SP-2Pelabuhan Batubara Tarahan
PT. Protech Asia Engineering.
See table 4, choice the Qt' corresponding with Belt width, trough angle, basic angle and find out;

By Pass System RCD-1 to SP3 RCD-2 to SP-2Pelabuhan Batubara Tarahan
PT. Protech Asia Engineering.
63.2238
53.837
58.574 63.337 power yang diminta
Recommended Pulley Diameter (mm) for Multiply Belt (4PN150) with 65% ~ 100 % utilization;