1 5 6 2 ELR96V24 ELR96 ELR ID: TR ID: A B ELR96 ELR96V24 …...Ι∆n (A) 3 0,5 0,4 0,2 0,3 0,1 0,06...
Transcript of 1 5 6 2 ELR96V24 ELR96 ELR ID: TR ID: A B ELR96 ELR96V24 …...Ι∆n (A) 3 0,5 0,4 0,2 0,3 0,1 0,06...
TEST RESET
ELR ID: TR ID:
IEC/EN 60947-2 Annex M
ON FAULT
0,5
0,3
1 1,52
Ι∆n (A)3 0,5
0,40,30,2
0,10,06
0
∆t (s)
ELR96
ONON FAUUULT
1 2 3 4 5 6 7 8 9 10 11 12
V aux. ouput relayTRIP
MADE IN ITALY
005A
s.n.
ELR96* V aux:5 - 6 = 110V ca/cc (±20%)5 - 7 = 230V ca (±20%)5 - 8 = 400V ca (±20%)
ELR96V24* V aux:5 - 6 = 24V ca/cc (±20%)5 - 7 = 48V ca/cc (±20%)
*
currenttransformer
TR...imput
current
ELR96
Aux
12
34
56
78
910
1112
ALIMENTAZIONETERRA N L1 L2 L3
TR... S2-
S1
T2-T
11
23
4
90
5618
20
92
92
R3
96
9696
TEST RESET
ELR ID: TR ID:
IEC/EN 60947-2 Annex M
ON FAULT
0,5
0,3
1 1,52
Ι∆n (A)3 0,5
0,40,30,2
0,10,06
0
∆t (s)
ELR96
Ι∆nx0,1
∆tx1manRes
Ι∆nx1Ι∆nx10
∆tx10autoRes
FAIL SAFE
offon
1 0
BC
A
DE
ELR962CSG152130R1202
ELR96V242CSG452130R1202
Relé differenziale elettronico da fronte quadro
Tipo A
Descrizione
Schema di collegamento
Legenda:1) - Regolazione della sensibilità IΔn2) - Regolazione del tempo di intervento 3) - Pulsante di test4) - Pulsante di reset5) - LED verde: segnalazione della presenza di alimentazione del dispositivo6) - LED rosso: intervento del relè7) - Morsettiera per l’alimentazione e la connessione del toroide e dei contatti in uscita
Caratteristiche tecniche Caratteristiche dimensionali (mm)
Tensione di alimentazione ausiliaria ELR96: 110, 230, 400 V ca / 110 V cc (±20%); 50-60Hz
ELR96V24P: 24-48 V ca/cc (±20%); 50-60Hz
Consumo max 4 VA
0,03 ÷ 0,3 A per K = 0,1
Regolazione sensibilità IΔn 0,3 ÷ 3 A per K = 1
3 ÷ 30 A per K = 10
Regolazione tempo di intervento t 0 ÷ 0,5 sec. per K = 1
0,5 ÷ 5 sec. per K = 10
Segnalazioni led ON, led FAULT
Trasformatori torodali Serie TR…
Portata del contatto in uscita 5 A 250V
Funzioni programmabili Fail Safe, Autoreset
Temperatura di funzionamento -10 ÷ 60°C
Temperatura di stoccaggio -20 ÷ 70°C
Umidità relativa ≤ 95 %
Prova di isolamento 2,5 kV 60 sec.
Posizione di montaggio Indifferente
Tipo di collegamento Tramite morsettiera a vite (sez max cavo 2,5 mm²)
Grado di protezione IP 52 frontale con calotta
(IP40 frontale) - IP 20 zona morsetti
Norme di riferimento CEI EN 60947-2 Annex-M
Esempio di collegamento con bobina di apertura a lancio di corrente. Per collegamento con bobina di minima tensione utilizzare i morsetti 10-11 del contatto di trip del relé.
Minidip
6 21 5
3 4
PannELLo antERioRE PannELLo PoStERioRE
7
Programmazione Minidip
A - Fail Safe in posizione 1: Fail Safe on in posizione 0: Fail Safe oFF B - Modalità di reset in posizione 1 il reset è automatico in posizione 0 il reset è manuale C - Impostazione della costante di moltiplicazione del tempo di intervento in posizione 1 K = 10 in posizione 0 K = 1 D/E - Impostazione della costante di moltiplicazione della sensibilità con D,E in posizione 0 K = 0,1 con D in posizione 1, E in posizione 0 K = 1 con D,E in posizione 1 K = 10
Alimentazione ausiliaria Vaux:ELR96• morsetti5-6=110Vca/cc(±20%)• morsetti5-7=230Vca(±20%)• morsetti5-8=400Vca(±20%)
ELR96V24• morsetti5-6=24Vca/cc(±20%)• morsetti5-7=48Vca/cc(±20%)
Connessione al trasformatore toroidale:Connettere i morsetti 1 e 2 all’avvolgimento di misura del toroide.
tERRaaLiMEntazionE
bobina aLanCio Di CoRREntE
2CS
G44
4009
D51
02
TEST RESET
ELR ID: TR ID:
IEC/EN 60947-2 Annex M
ON FAULT
0,5
0,3
1 1,52
Ι∆n (A)3 0,5
0,40,30,2
0,10,06
0
∆t (s)
ELR96
ONON FAUUULT
1 2 3 4 5 6 7 8 9 10 11 12
V aux. ouput relayTRIP
MADE IN ITALY
005A
s.n.
ELR96* V aux:5 - 6 = 110V ca/cc (±20%)5 - 7 = 230V ca (±20%)5 - 8 = 400V ca (±20%)
ELR96V24* V aux:5 - 6 = 24V ca/cc (±20%)5 - 7 = 48V ca/cc (±20%)
*
currenttransformer
TR...imput
current
90
5618
20
92
92
R3
96
9696
TEST RESET
ELR ID: TR ID:
IEC/EN 60947-2 Annex M
ON FAULT
0,5
0,3
1 1,52
Ι∆n (A)3 0,5
0,40,30,2
0,10,06
0
∆t (s)
ELR96
Ι∆nx0,1
∆tx1manRes
Ι∆nx1Ι∆nx10
∆tx10autoRes
FAIL SAFE
offon
1 0
BC
A
DE
ELR96
Aux
12
34
56
78
910
1112
ALIMENTAZIONETERRA N L1 L2 L3
TR... S2-
S1
T2-T
11
23
4
ELR962CSG152130R1202
ELR96V242CSG452130R1202
Front panel residual current relay
A Type
Legenda:1) - Sensitivity setting IΔn2) - Delay time setting3) - Test pushbutton4) - Reset pushbutton5) - GREEN Led: auxiliary supply presence6) - RED Led: trip contact intervention7) - Terminals for output contacts connection, auxiliary supply and toroidal connection
Auxiliary Power Supply ELR96: : 110 V ac/dc; 230, 400 V ac (±20%); 50-60 Hz
ELR96V24P: : 24-48 V ac/dc (±20%); 50-60 Hz
Maximum consumption 4 VA
0,03 ÷ 0,3 A with K = 0,1
Sensitivity setting IΔn 0,3 ÷ 3 A with K = 1
3 ÷ 30 A with K = 10
Delay time setting 0 ÷ 0,5 sec. with K = 1
0,5 ÷ 5 sec. with K = 10
Signallings led ON, led FAULT
Toroidal transformers TR range
Output contact capacity 5 A 250V
Adjustable features Fail Safe, Autoreset
Operating temperature -10 ÷ 60°C
Storage temperature -20 ÷ 70°C
Max humidity ≤ 95 %
Dielectric test 2,5 kV 60 sec.
Mounting position Any
Wiring type Screw terminals/ cross section cables 2,5 mm²
Protection degree IP52 frontal with cover
(IP40 frontal) - IP20 terminals
Standard IEC EN 60947-2 Annex-M
Wiring diagram with shunt trip Connect the terminals 10 and 11 when undervoltage release is used.
Minidip
6 21 5
3 4 7
A - Fail Safe position 1: Fail Safe ON position 0: Fail Safe OFF B - Reset Mode position 1: automatic reset position 0: manual reset C - Delay time multiplication constant position 1: K = 10 position 0: K = 1 D/E - Sensitivity multiplication constant D,E in position 0: K = 0,1 D in position 1, E in position 0: K = 1 D,E in position 1 K = 10
Auxiliary Power Supply Vaux:ELR96• Terminals5-6=110Vac/dc(±20%)• Terminals5-7=230Vac(±20%)• Terminals5-8=400Vac(±20%)
ELR96V24• Terminals5-6=24Vac/dc(±20%)• Terminals5-7=48Vac/dc(±20%)
Toroidal transformer connection:To link the terminals 1 and 2 with toroidal terminals S1 and S2
Description
FRONTVIEW REARVIEW
Connection
Minidip Set Up
Technical features Dimensions (mm)
SHUNTTRIP
EaRThSuppLy
2CS
G44
4009
D51
02