Technical Data Sheet IG2 Metis & Namur II - Rail...

Post on 12-Jul-2018

215 views 0 download

Transcript of Technical Data Sheet IG2 Metis & Namur II - Rail...

Characteristic Unit Note

Injector Version N° of cylinders

Material body and treatment

Working pressure

Max pressure

Rated voltage (at coil) Volt

Minimum copper wire section

for coil connectionmm2

Coil type by encoding A2 A3

Resistance Ω 2 3 ± 5% at T= 25°

Suggested peak current time

(duration)ms 4,2 4,5

Suggested peak current value A

Suggested holding current

(±10%)A

Cold Starting Requirements

Complete OPENING Response

Timems 2,8 3,2

Complete CLOSING Response

Timems 2,8 2,8

Minimum injection pulse ms 2,8 3,2

tested with 2 mm nozzle

diameter at 14V ∆p=1bar

T= 25°C

Stroke Micron

Seat Diameter mm

Static flow rate (with max

nozzle Φ) for 1 single injector

at 20°C (with air)

SLPM (sL/min) at 1 bar inlet pressure

gr/sec at 1 bar inlet pressure

Kg/h at 1 bar inlet pressure

gr/sec at 1 bar inlet pressure

Kg/h at 1 bar inlet pressure

Leakage (tested with air) cc/h

Noise level dB ±1 dB Rail Test Condition

Compatibility with gas

Driver Stage

(±10% - total injection time

5 ms) ± 5% tested without

nozzle at 14V Dp=1bar T=

25°C

7,86

From 0,5 a 2,0 (7 to 29)

3,0 (47)

10,8 - 14,4

0,75

1

1

Value

IG2 Metis - Aluminium red anodized

IG2 Namur II - Brass sandblasted

LPG, CNG

Relative Pressure Bar (Psi)

Peak and Hold (PWM)

Calculated max flow rate(with

max nozzle Φ) for 1 single

injector LPG at 20°C

3,88

13,95

≤ 15

64

Increase up to 20% the "peak current time" for first

cycles when gas temperature is < 10°C

600

3,8

146

Calculated max flow rate(with

max nozzle Φ) for 1 single

injector CNG at 20°C (G20

CNG fluid)

2,18

Technical Data Sheet IG2 Metis & Namur II

Coil Connector type

About connecting wire,

refer to our drawing, code

114.01.AMP.001

Inlet gas fitting for rubber hose mm

Outlet gas fitting

Calibrated hole ᴓ range (for

nozzles)ᴓ

Approvals

Operating Ambient Temp

Range°C

Principle of operation

Power handling capability LPG HP/cyl

Power handling capability

CNG HP/cyl

Coil IP Rating

Characteristic Unit Note

Injector Version N° of cylinderspossibility to mount injectors

separately from manifold

Material body and treatment

Working pressure

Max pressure

Rated voltage (at coil) Volt

Minimum copper wire section

for coil connectionmm2

Coil type by encoding A2 A3

Resistance Ω 2 3 ± 5% at T= 25°

Suggested peak current time

(duration)ms 4,2 4,5

Suggested peak current value A

Suggested holding current

(±10%)A

Cold Starting Requirements

1,2,3,4

Polymer black

From 0,5 to 2,0 (7 to 29)

3,0 (47)

10,8 - 14,4

0,75

1

Increase up to 20% the "peak current time" for first

cycles when gas temperature is < 10°C

Value

IP67

From 1,00 to 3,50 mm

(0,25 mm step)

110R-00 67R-01

(-40°C / +120°C)

Solenoid valve - Normally closed - Mobile Plunger

1 bar up to 50 HP/cyl

2 bar up to 45 HP/cyl

Relative Pressure Bar (Psi)

RAIL S.r.l - Via A.Grandi 16, 42030 Vezzano Sul Crostolo - Reggio Emilia - Italia

Technical Data Sheet IG5 Noumea

2 way Amp/Delphi super

seal fermale connector

with tab contacts

ᴓ 7 mm

Calibrated nozzles M8x1 for rubber hose ᴓ 4 mm - ᴓ 5

mm - ᴓ 6 mm

Complete OPENING Response

Timems 2,6 3

Complete CLOSING Response

Timems 2,5 2,5

Minimum injection pulse ms 2,6 3

tested with 2 mm nozzle

diameter at 14V ∆p=1bar

T= 25°C

Stroke Micron

Seat Diameter mm

Static flow rate (with max

nozzle Φ) for 1 single injector

at 20°C (with air)

SLPM (sL/min) at 1 bar inlet pressure

gr/sec at 1 bar inlet pressure

Kg/h at 1 bar inlet pressure

gr/sec at 1 bar inlet pressure

Kg/h at 1 bar inlet pressure

Leakage (tested with air) cc/h

Noise level dB ±1 dB Rail Test Condition

Compatibility with gas

Driver Stage

Coil Connector type

About connecting wire,

refer to our drawing, code

114.01.AMP.001

Inlet gas fitting for rubber hose mm

Outlet gas fitting

Calibrated hole ᴓ range (for

nozzles)ᴓ

max flow rate with 3,8 mm

nozzles diameter

Approvals

Operating Ambient Temp

Range°C

Principle of operation

Power handling capability LPG HP/cyl

Power handling capability

CNG HP/cyl

Coil IP Rating

(±10% - total injection time

5 ms) ± 5% tested without

nozzle at 14V Dp=1bar T=

25°C

2 bar up to 50 HP/cyl with 3,8 mm nozzles diameter

IP67

ᴓ10 mm / ᴓ12 mm / ᴓ14 mm / ᴓ16 mm

ᴓ 7 mm for single injector mountig

Calibrated nozzles for rubber hose ᴓ 6 mm -

Available nozzle for direct mounting on engine

manifold in case of single injector mounting

From 1,00 to 3,50 mm

(0,25 mm step)

110R-00 67R-01

(-40°C / +120°C)

Solenoid valve - Normally closed - Mobile Plunger

≤ 15

63

LPG, CNG

Peak and Hold (PWM)

2 way Amp/Delphi super

seal fermale connector

with tab contacts

145

2,17

7,81

3,85

13,86

Calculated max flow rate(with

max nozzle Φ) for 1 single

injector CNG at 20°C (G20

CNG fluid)

Calculated max flow rate(with

max nozzle Φ) for 1 single

injector LPG at 20°C

1 bar up to 60 HP/cyl with 3,8 mm nozzles diameter

600

3,8

RAIL S.r.l - Via A.Grandi 16, 42030 Vezzano Sul Crostolo - Reggio Emilia - Italia